UltraVNC Release Notes

**********************************************
* Ultr@VNC – Latest modifications – History

** V1.2.0.1 Aug 2014

*service, fix error 1314, server sometimes failed to start desktop part and closed winvnc.
*security: increase timeout after each wrong password to make brute force hacking harder
*color correction 16bit and mirror driver*memory leak with mirror driver fixed in previous fix
*save setting permission fix
*added support for new repeater with keepalive
*tooltip buffer overrun fix, cause server to fail when sting in systray was to long
( multiple ethernet card. Long hostnames etc…)

**V1.1.9.6 Dec 2013

*auto alpha blending based on OS*zrle deadlock fix
*tight encoding fixed
*show screenbuildup on first run
*server fix bug that crashed iexplorer 8

**V1.1.9.4 Okt 2013

*viewer mod for vmware ( wrong colors)
*update lijpeg-turbo to 1.3.0

**V1.1.9.3 Aug 2013
-Missing screen  refresh  ( when driver selected but not used)
-Factory reset ( when temp was not writable)

**V1.1.9.2 Aug 2013
-Mirror driver and begative screen coordinates (left secondary desktop)

**V1.1.9.0 May 2013
-fixed change ip detection, sometimes server was disconnected after a few seconds by a false positive
-new installer xp64 wasn’t supported

**V1.1.8.9 April 2013
-Viewer timeout option grayscreen fix
-server leaks fixed

**V1.1.8.8 March 2013
-server crash
-server grayscreen on startup loop fixed

**V1.1.8.7 March 2013
-filetransfer bug fix (x64)

**V1.1.8.6 March 2013
-autoreconnect and auth fail fix
-viewer with option window open fails to close
-viewer messagebox sometimes hidden behind window

**V1.1.8.5 March 2013
deadlock softcursor fixed (viewer)
**V1.1.8.4 March 2013
server
-u2 encode on 16 color display crash
viewer
-fullscreen bar center
-recoonect set by default

**V1.1.8.3 March 2013

-Fix server /NULL crash
-Fix radio button u2 viewer

**V1.1.8.2 March 2013
-fix lock after gray screen

**v1.1.8.2 (March 2013)
-disconnect after gray screen
**v1.1.8 (Nov 2012)
-addad support windows 8
( new capture engine)
-several bug fixes
-better multi monitor support
-new vncpasswd + encryption.
Instead of using the password as part of the encryption, we now check the password insite the encryption by the server. This allow the server to balcklist servers
after x fault password.